The HA remote IP monitoring configuration also involves setting a flip timeout. The flip timeout is required to reduce the frequency of failovers if, after a failover, HA remote IP monitoring on the new primary unit also causes a failover. This can happen if the new primary unit cannot connect to one or more of the monitored remote IP addresses. The result could be that until you fix the network problem that blocks connections to the remote IP addresses, the cluster will experience repeated failovers. You can control how often the failovers occur by setting the flip timeout. The flip timeout stops HA remote IP monitoring from causing a failover until the primary unit has been operating for the duration of the flip timeout.

If you set the flip timeout to a relatively high number of minutes you can find and repair the network problem that prevented the cluster from connecting to the remote IP address without the cluster experiencing very many failovers. Even if it takes a while to detect the problem, repeated failovers at relatively long time intervals do not usually disrupt network traffic.

Use the following command to set the flip timeout to 3 hours (360 minutes):

config system ha

set pingserver-flip-timeout 360 end


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Monitoring multiple IP addresses from one interface

Monitoring multiple IP addresses from one interface

You can add multiple IP addresses to a single link monitor to use HA remote IP monitoring to monitor more than one IP address from a single interface. If you add multiple IP addresses, the health checking will be with all of the addresses at the same time. The link monitor only fails when no responses are received from any of the addresses.

config system link-monitor edit port2

set server 192.168.20.20 192.168.20.30 172.20.12.10 end


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Changing the link monitor failover threshold

Changing the link monitor failover threshold

If you have multiple link monitors you may want a failover to occur only if more than one of them fails.

For example, you may have 3 link monitors configured on three interfaces but only want a failover to occur if two of the link monitors fail. To do this you must set the HA priorities of the link monitors and the HA pingserver- failover-threshold so that the priority of one link monitor is less than the failover threshold but the added priorities of two link monitors is equal to or greater than the failover threshold. Failover occurs when the HA priority of all failed link monitors reaches or exceeds the threshold.

For example, set the failover threshold to 10 and monitor three interfaces:

 

config system ha

set pingserver-monitor-interface port2 port20 vlan_234 set pingserver-failover-threshold 10

set pingserver-flip-timeout 120 end

Then set the HA priority of link monitor server to 5.

 

The HA Priority (ha-priority) setting is not synchronized among cluster units. In the fol- lowing example, you must set the HA priority to 5 by logging into each cluster unit.

config system link-monitor edit port2

set server 192.168.20.20 set ha-priority 5

next

edit port20

set server 192.168.20.30 set ha-priority 5

next

edit vlan_234

set server 172.20.12.10

set ha-priority 5 end

If only one of the link monitors fails, the total link monitor HA priority will be 5, which is lower than the failover threshold so a failover will not occur. If a second link monitor fails, the total link monitor HA priority of 10 will equal the failover threshold, causing a failover.

By adding multiple link monitors and setting the HA priorities for each, you can fine tune remote IP monitoring.

For example, if it is more important to maintain connections to some networks you can set the HA priorities higher for these link monitors. And if it is less important to maintain connections to other networks you can set the HA priorities lower for these link monitors. You can also adjust the failover threshold so that if the cluster cannot connect to one or two high priority IP addresses a failover occurs. But a failover will not occur if the cluster cannot connect to one or two low priority IP addresses.


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Adding HA remote IP monitoring to multiple interfaces

Adding HA remote IP monitoring to multiple interfaces

You can enable HA remote IP monitoring on multiple interfaces by adding more interface names to the pingserver-monitor-interface keyword. If your FortiGate configuration includes VLAN interfaces, aggregate interfaces and other interface types, you can add the names of these interfaces to the pingserver- monitor-interface keyword to configure HA remote IP monitoring for these interfaces.

For example, enable remote IP monitoring for interfaces named port2, port20, and vlan_234:

config system ha

set pingserver-monitor-interface port2 port20 vlan_234 set pingserver-failover-threshold 10

set pingserver-flip-timeout 120 end

 

Then configure health monitors for each of these interfaces. In the following example, default values are accepted for all settings other than the server IP address.

 

config system link-monitor edit port2

set server 192.168.20.20 next

edit port20

set server 192.168.20.30 next

edit vlan_234

set server 172.20.12.10 end


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Remote link failover

Remote link failover

Remote link failover (also called remote IP monitoring) is similar to HA port monitoring and link health monitoring (also known as dead gateway detection). Port monitoring causes a cluster to failover if a monitored primary unit interface fails or is disconnected. Remote IP monitoring uses link health monitors configured for FortiGate interfaces on the primary unit to test connectivity with IP addresses of network devices. Usually these would be IP addresses of network devices not directly connected to the cluster. For example, a downstream router. Remote IP monitoring causes a failover if one or more of these remote IP addresses does not respond to link health checking.

By being able to detect failures in network equipment not directly connected to the cluster, remote IP monitoring can be useful in a number of ways depending on your network configuration. For example, in a full mesh HA configuration, with remote IP monitoring, the cluster can detect failures in network equipment that is not directly connected to the cluster but that would interrupt traffic processed by the cluster if the equipment failed.

 

Example HA remote IP monitoring topology

In the simplified example topology shown above, the switch connected directly to the primary unit is operating normally but the link on the other side of the switches fails. As a result traffic can no longer flow between the primary unit and the Internet.

To detect this failure you can create a link health monitor for port2 that causes the primary unit to test connectivity to 192.168.20.20. If the health monitor cannot connect to 192.268.20.20 the cluster to fails over and the subordinate unit becomes the new primary unit. After the failover, the health check monitor on the new primary unit can connect to 192.168.20.20 so the failover maintains connectivity between the internal network and the Internet through the cluster.

 

To configure remote IP monitoring

1. Enter the following commands to configure HA remote monitoring for the example topology.

  • Enter the pingserver-monitor-interface keyword to enable HA remote IP monitoring on port2.
  • Leave the pingserver-failover-threshold set to the default value of 5. This means a failover occurs if the link health monitor doesn’t get a response after 5 attempts.
  • Enter the pingserver-flip-timeout keyword to set the flip timeout to 120 minutes. After a failover, if HA remote IP monitoring on the new primary unit also causes a failover, the flip timeout prevents the failover from occurring until the timer runs out. Setting the pingserver-flip-timeout to 120 means that remote IP monitoring can only cause a failover every 120 minutes. This flip timeout is required to prevent repeating failovers if remote IP monitoring causes a failover from all cluster units because none of the cluster units can connect to the monitored IP addresses.

 

config system ha

set pingserver-monitor-interface port2 set pingserver-failover-threshold 5

set pingserver-flip-timeout 120 end

2. Enter the following commands to add a link health monitor for the port2 interface and to set HA remote IP

monitoring priority for this link health monitor.

  • l  Enter the detectserver keyword to set the health monitor server IP address to 192.168.20.20.
  • l  Leave the ha-priority keyword set to the default value of 1. You only need to change this priority if you change the HA pingserver-failover-threshold. The ha-priority setting is not synchronized among cluster units.

The ha-priority setting is not synchronized among cluster units. So if you want to change the ha-priority setting you must change it separately on each cluster unit. Otherwise it will remain set to the default value of 1.

  • Use the interval keyword to set the time between link health checks and use the failtime keyword to set the number of times that a health check can fail before a failure is detected (the failover threshold). The following example reduces the failover threshold to 2 but keeps the health check interval at the default value of 5.

config system link-monitor edit ha-link-monitor

set server 192.168.20.20 set srcintf port1

set ha-priority 1 set interval 5

set failtime 2 end


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Subsecond failover

Subsecond failover

On FortiGate models 395xB and 3x40B HA link failover supports subsecond failover (that is a failover time of less than one second). Subsecond failover is available for interfaces that can issue a link failure system call when the interface goes down. When an interface experiences a link failure and sends the link failure system call, the FGCP receives the system call and initiates a link failover.

For interfaces that do not support subsecond failover, port monitoring regularly polls the connection status of monitored interfaces. When a check finds that an interface has gone down, port monitoring causes a link failover. Subsecond failover results in a link failure being detected sooner because the system doesn’t have to wait for the next poll to find out about the failure.

Subsecond failover can accelerate HA failover to reduce the link failover time to less than one second under ideal conditions. Actual failover performance may be vary depending on traffic patterns and network configuration. For example, some network devices may respond slowly to an HA failover.

No configuration changes are required to support subsecond failover. However, for best subsecond failover results, the recommended heartbeat interval is 100ms and the recommended lost heartbeat threshold is 5 (see Modifying heartbeat timing on page 1505).

config system ha

set hb-lost-threshold 5 set hb-interval 1

end

For information about how to reduce failover times, see Failover performance on page 1550.


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Happy 7 Months Anniversary!

Happy to say that Fortinet GURU turned 7 months old today! The site has come a long ways in this short amount of time. Really excited for the direction and new content that is coming down the pipe!


Having trouble configuring your Fortinet hardware or have some questions you need answered? Check Out The Fortinet Guru Youtube Channel! Want someone else to deal with it for you? Get some consulting from Fortinet GURU!

Monitoring VLAN interfaces

Monitoring VLAN interfaces

If the FortiGates in the cluster have VLAN interfaces, you can use the following command to monitor all VLAN interfaces and write a log message if one of the VLAN interfaces is found to be down.

Once configured, this feature works by verifying that the primary unit can connect to the subordinate unit over each VLAN. This verifies that the switch that the VLAN interfaces are connected to is configured correctly for each VLAN. If the primary unit cannot connect to the subordinate unit over one of the configured VLANs the primary unit writes a link monitor log message indicating that the named VLAN went down (log message id 20099). Use the following CLI command to enable monitoring VLAN interfaces:

config system ha-monitor

set monitor-vlan enable/disable

set vlan-hb-interval <interval_seconds>

set vlan-hb-lost-threshold <vlan-lost-heartbeat-threshold>

end

vlan-hb-interval is the time between sending VLAN heartbeat packets over the VLAN. The VLAN

heartbeat range is 1 to 30 seconds. The default is 5 seconds.

 

vlan-hb-lost-threshold is the number of consecutive VLAN heartbeat packets that are not successfully received accross the VLAN before assuming that the VLAN is down. The default value is 3, meaning that if 3 heartbeat packets sent over the VLAN are not received then the VLAN is considered to be down. The range is 1 to 60 packets.

A VLAN heartbeat interval of 5 means the time between heartbeat packets is five seconds. A VLAN heartbeat threshold of 3 means it takes 5 x 3 = 15 seconds to detect that a VLAN is down.